★Product Introduction
The ZGSL-Z-1500-13.8-0.415 is a radial feed pad-mounted transformer designed for
underground power distribution networks. It steps down 13.8kV primary voltage to 0.415kV
secondary voltage, delivering 1500kVA capacity for commercial and industrial
applications.
Housed in a locked, weatherproof steel enclosure, this electrical transformer ensures
safe operation in compact spaces without requiring fenced enclosures. Key features
include:
- ✔ High-efficiency design (up to 98.5% energy efficiency)
- ✔ Radial feed configuration for simplified underground cable connections
- ✔ Corrosion-resistant construction for outdoor durability
Ideal for utility service drops, this pad-mounted transformer provides reliable power
conversion while meeting IEEE and IEC standards.
★Product Advantage
-
Superior Cost Efficiency (vs Loop Feed)
The radial feed design reduces infrastructure costs by approximately 25% due to
simpler cabling requirements. This transformer maintains 98.5% efficiency (3.2kW
no-load / 18.5kW load losses), verified by ISO 9001-certified testing.
-
Compact & Space-Saving Design
With dimensions of just 2.1×1.8×1.9m, this pad mounted transformer is ideal for
space-constrained sites. The radial configuration eliminates complex switching gear,
saving up to 35% footprint compared to loop feed alternatives.
-
Reliability and Durability
Built to withstand harsh environmental conditions, the transformer features a robust
design for long service life. It resists weather, vandalism, and wildlife
interference, ensuring consistent and reliable power distribution.
-
Ease of Installation and Maintenance
Ground-level placement simplifies installation, requiring only a concrete pad and
electrical connections. This accessibility also makes routine maintenance and
inspections more straightforward, reducing operational costs and downtime.
-
Enhanced Security
Lockable enclosures provide an additional layer of security, protecting against
unauthorized access and tampering. This is especially important in areas susceptible
to vandalism or where public safety is a concern.
Technical Parameters
Type |
Pad mounted transformer-Radial feed |
Model |
ZGS-Z-1500/13.8-0415 |
Installation |
Outdoor |
Altitude |
≤1000m |
Rated Power |
1500KVA |
Cooling Method |
KNAN |
Primary Voltage |
13.8kV |
Secondary Voltage |
415Y/240V |
Rated Frequence |
60HZ |
Insulation oil |
FR3 |
Tapping Range |
±2×2.5% |
Temperature rise(℃) |
65 |
Connection Group |
Dyn1 |
Impendace % |
5-7.5% |
Dimensions(mm) |
1900*2640*2150 |
Total weight(kg) |
8030 |
Product Uses
Radial Feed Pad-Mounted Transformer Applications
- Residential Subdivisions: Ideal for housing developments with
single-source power feeds.
- Small Commercial Buildings: Suitable for retail stores, offices,
and schools where redundancy is not critical.
- Rural Electrification: Used in remote areas with simple grid
layouts.
- Temporary Power Supply: Deployed for construction sites or
emergency power restoration.
Advantages of Radial Feed
- ✔ Lower Installation Cost (25-30% savings vs. loop feed)
- ✔ Simpler Design (Single power input reduces cabling complexity)
- ✔ Faster Commissioning (Can be installed in 6-8 hours)
- ✔ Easier Maintenance (Fewer components to inspect)
Loop Feed Pad-Mounted Transformer Applications
- Urban Grids & Smart Cities: Used in networked distribution
systems requiring high reliability.
- Industrial Parks: Ensures uninterrupted power for factories and
manufacturing plants.
- Critical Facilities: Hospitals, data centers, and airports where
power redundancy is essential.
- Renewable Energy Integration: Supports microgrids with multiple
power sources.
When to Choose Loop Feed?
- ✔ Need automatic backup power (N-1 redundancy)
- ✔ Require minimal downtime during maintenance
- ✔ Operating in high-load, complex grids
Why Choose Radial Feed? Key Benefits
- Cost-Effective
Saves ¥15,000–20,000 per unit in cable and
switching gear costs.
- Space-Saving
30% smaller footprint than loop feed, ideal for
tight urban spaces.
- Lower Maintenance
50% fewer inspection points, reducing
long-term servicing costs.
- Faster Deployment
Plug-and-play design enables quick
installation in under 8 hours.
Product Operate Guide
1. Shipment, Handling, Rigging & Storage
- Inspect the transformer for shipping damage upon arrival. Report any issues to
the carrier immediately.
- Use only designated lifting lugs and appropriate rigging equipment rated for the
transformer’s weight. Never lift by bushings or radiators.
- Store the transformer upright on a level, dry surface. Protect from weather and
flooding. For long-term storage, seal all openings and monitor silica gel
breathers.
2. Transformer Installation
- Crane Lifting & Rigging: Attach slings to marked lifting
points. Use spreader bars if needed to avoid tank deformation.
- Jack & Skid: For short moves, use jacks and skids under the
base. Move slowly and avoid sudden movements.
- Foundation: Place transformer on a flat, solid, non-combustible
pad with proper drainage. Anchor as required by local codes.
- Compartment: Ensure HV and LV compartments are accessible and
free of debris. Check gasket seals for integrity.
- Grounding: Connect tank and neutral points to a reliable earth
ground per IEEE/NEC standards.
- High Voltage & Low Voltage Connections: Clean and torque
all cable terminations to manufacturer’s specifications. Use proper lugs and
insulation.
- Dielectric Fluid: Check oil level and top up with approved
fluid if necessary. Sample oil for moisture and dielectric strength if required.
- Transformer Pressure: Verify pressure relief device is
operational. Check for correct internal pressure or vacuum as specified.
- Other Aspects: Install required signage and barriers. Confirm
all accessories are installed and functional.
3. Pre-Energization
- Perform insulation resistance and turns ratio tests. Confirm all connections are
tight and correct.
- Verify tap changer is set to the correct position.
- Check oil level, absence of leaks, and operation of gauges and alarms.
4. Post-Energization
- Monitor for abnormal noise, vibration, or temperature rise.
- Check for oil leaks and monitor gauges for pressure and temperature.
- Record initial load and voltage readings.
5. Switching Operation
- Operate switches only under no-load conditions unless rated for load-break.
- Follow lockout/tagout procedures before maintenance.
- Use insulated tools and wear appropriate PPE.
6. Protection
- Ensure fuses, surge arresters, and relays are installed and rated correctly.
- Test protection devices per manufacturer’s recommendations.
7. Accessories
- Check operation of temperature gauges, pressure relief devices, oil level
indicators, and gas relays.
- Maintain and calibrate accessories as required.
8. Maintenance
- Perform periodic inspections for leaks, corrosion, and proper operation of all
devices.
- Sample and test dielectric fluid annually or as recommended.
- Clean bushings and compartments regularly.
9. Field Acceptance Test Guidelines
- Conduct insulation resistance, turns ratio, and winding resistance tests before
energization.
- Compare results with factory test reports and standards (e.g., IEEE C57.12).
- Document all test results for future reference.
10. Tables and Procedures
- Refer to the manufacturer’s manual for torque values, oil specifications, and
test limits.
- Maintain a log of all inspections, tests, and maintenance activities.
- Follow standard operating procedures for all field operations.